Quaternion Pathfinder · PF-002 research slice

Virtual lab - simulated experiment

Can two force sensors distinguish optical recoil from interference?

Which simulated instrument imperfections prevent reliable separation, and what would need to improve?

Reviewed research publication. This is not a physical measurement or a canonical technology-acceptance result.

In plain English

Understanding this experiment

What is being measured?
A simulated light source changes between two phase settings. Two simulated force sensors are subtracted, and their force contrast is compared with a prediction from the outgoing light. No physical force was measured.
Why does it matter?
Light carries momentum, so an emitter feels a tiny backwards force: ordinary radiation recoil. An experiment must separate that signal from heat, vibration and sensor changes before attributing a reading to the source. A failed simulated control identifies a design limitation, not the limit of every possible design.
How does the title relate?
PF-002 studies the measurement apparatus for ordinary radiation recoil. The mechanistic robustness slice asks which imperfections limit that apparatus, not whether a new propulsion mechanism exists.

Setup, objective and goal

How the experiment works

Objective
Find what prevents the two-channel instrument distinguishing the predicted optical recoil from unwanted forces.
Goal
Test a predeclared separation requirement with channel-envelope calculations, adverse controls and fresh simulated seeds; retain failures and unresolved explanations.
THE CONCEPTUAL SETUP

A tiny source force. Two imperfect readings.

Virtual lab - simulated experiment. Proposed arrangement, not built apparatus.

Conceptual optical source, primary force sensor and reference force sensorLight leaves a source supported by a primary force sensor. A solid left arrow marks source recoil. A separate reference sensor reads shared disturbance and may receive source leakage, shown dashed. Both readings enter a weighted subtraction. This is a schematic, with no measured dimensions, force magnitudes or hardware design.Outgoing lightRecoilLeakageSourcePrimary sensorReference sensorShared disturbance reaches bothWeighted differenceP - w × RContrast + uncertainty
Conceptual schematic. Solid arrows: source recoil and light direction. Dashed path: possible source leakage. Dotted lines: readings, not forces. Positions and arrow lengths are illustrative, not measured. Follow the retained instrument model.
01 · Optical recoilThe signal we want. Changing the light's phase setting changes the source's recoil. The primary channel reads that force; some source signal can also leak into the reference. Schematic arrows do not encode magnitudes.PrimaryReferenceSource forcePossible leakageA source-correlated contrast

The signal we want

Changing the light's phase setting changes the source's recoil. The primary channel reads that force; some source signal can also leak into the reference.

02 · Shared disturbanceThe disturbance we subtract. A common disturbance reaches both channels. Subtraction helps only when their responses and the reference weight are sufficiently well matched. Schematic arrows do not encode magnitudes.PrimaryReferenceDisturbanceDisturbanceMatched subtraction helps

The disturbance we subtract

A common disturbance reaches both channels. Subtraction helps only when their responses and the reference weight are sufficiently well matched.

03 · Changing channel balanceThe false signal we must catch. If gain or subtraction weight changes with the phase labels, a shared disturbance can survive subtraction and look like a source signal. Schematic arrows do not encode magnitudes.PrimaryReferenceDisturbanceChanged readingA residual can mimic signal

The false signal we must catch

If gain or subtraction weight changes with the phase labels, a shared disturbance can survive subtraction and look like a source signal.

These three panels explain mechanisms in the retained model, not separate measured outcomes. Inspect the source record and controls.

A crucial control

Turn the source around. What follows it?

A force with the right size is not enough. Compare the same instrument in opposite source orientations.

Optical recoil

Optical recoil: reverses when source orientation reverses. Arrows show direction only, not measured force.Original sourceTurned sourceReverses

Consistent with recoil, but not unique to it.

Lab-fixed force

Lab-fixed force: does not reverse when source orientation reverses. Arrows show direction only, not measured force.Original sourceTurned sourceDoes not reverse

The orientation comparison can distinguish it.

Source-fixed impostor

Source-fixed impostor: reverses too when source orientation reverses. Arrows show direction only, not measured force.Original sourceTurned sourceReverses too

Still indistinguishable from recoil here.

Direction-only schematic of the orientation control. The pointed end of each source indicates its light direction; force arrows show the direction being compared. Recoil and a source-fixed impostor remain observationally identical in this model. Inspect the retained attribution controls.

Inspect the full technical signal-flow schematic
PF-002 mechanistic robustness study version 1: setup, objective and goal Conceptual schematic of a simulated experiment, not to scale. Phase-paired optical trials drive a primary and a reference force channel. Six stress points are marked: phase and feed mismatch set once per trial, reference leakage, response mismatch, read noise, transfer knowledge and label-synchronous gain or weight wander. The weighted difference gives a force contrast with an interval. A finite detector gives an optical interval, mapped through a bounded transfer so both are compared in one channel domain. Rejection needs the worst-case null error plus the reported half-width to stay at least 1 pN below the lower edge of the predicted window. A second panel shows the two-orientation test: recoil reverses with the source, a lab-fixed force does not and is detected, and a source-fixed force reverses too and cannot be separated. All values are virtual. What stops the instrument separating optical recoil from interference? Virtual lab - simulated experiment. Conceptual schematic, not to scale; no measured calibration. Objective: find which mechanism limits separation. Goal: a predeclared requirement, tested by exact envelopes, adversarial witnesses and fresh seeds. Optical source A/B phase pairs 1 per-trial mismatch Primary channel response, thermal lag 4 read noise Reference channel 3 response mismatch 4 read noise force, shared 2 leakage (dashed) Weighted difference primary - weight x reference 6 gain or weight wander locked to A/B labels Finite detector raw optical interval Bounded transfer 5 transfer knowledge One channel domain 0 force interval predicted (dashed) Require all three: signal margin at least 1 pN control margin at least 1 pN truth inside every interval Worst case: lower window edge minus error minus half-width Why a size comparison is not enough: turn the source around A force correlated with phase and inside the predicted window looks identical in one orientation. Reversing the source splits three cases. Optical recoil reverses: consistent Lab-fixed impostor does not reverse: detected Source-fixed impostor reverses too: cannot be separated Upper arrow: orientation +1. Lower arrow: orientation -1. Dashed: source-fixed force. Source: pf002_mechanistic_robustness_v1.py
Conceptual schematic, not to scale. Solid lines show model couplings; the dashed path is reference leakage. Numbered labels identify varied imperfections. In the orientation panel, the upper and lower arrows show opposite source orientations; dashed arrows identify the source-fixed impostor. Inspect the retained model results.

Equivalent explanation: Phase-paired light drives the primary sensor and leaks partly into the reference sensor. Their weighted difference is compared with a finite detector prediction in one measurement domain. A shared disturbance cancels only if channel balance stays sufficiently stable. Recoil reverses when the source turns around; a laboratory-fixed force does not, but a source-fixed impostor reverses too and cannot be separated here.

Virtual lab - simulated experiment

Layer one · Plain-language outcome

What this research slice found

The original coupled comparison looked successful, but it compared force and optical intervals in different measurement domains. Correcting that in version 2 left the force-decoupled control rejected in only five of eight seeds. That is the retained negative result, not an apparatus success. The later robustness study explains the limitation: changes in sensor gain and subtraction weight that follow the phase labels leak the larger shared disturbance into the signal.

Virtual lab - simulated experiment

Layer two · What the evidence means

What the findings do and do not establish

Better read noise alone does not restore a worst-case margin in this model. Better-known or steadier channel balance can, at assumed levels. The all-improved configuration clears the predeclared requirement conditionally; it does not overturn the earlier negative result, because it changes the assumed apparatus. Turning the source around distinguishes a laboratory-fixed impostor, but a force that reverses with the source remains indistinguishable from recoil. A resolved contrast is therefore not attribution to optical recoil.

A margin is the separation remaining after the model's error allowance. Positive margins clear a model requirement only when the other controls and truth audits also hold. A piconewton (pN) is one trillionth of a newton. Values below use the retained tier-B analysis; force values are rounded to two decimal places in pN, while downloads preserve full precision.

Read the margin, not just the outcome

How much separation is left?

Virtual lab - simulated experiment. Retained tier-B margins, not physical force measurements.

The baseline and the all-improved configuration use different apparatus assumptions. This is not a before-and-after hardware test.

BaselineControl margin
-8.76 pN
BaselineSignal margin
-3.62 pN
All-improved assumptionsControl margin
7.89 pN
All-improved assumptionsSignal margin
13.51 pN
Solid vertical line: zero. Dashed vertical line: the 1.00 pN requirement. Hatched bars: control margins; solid bars: signal margins. Bar lengths use exact retained values on one shared linear scale; labels round to two decimal places. Clearing the line alone does not establish qualification: the other controls and truth audits must also hold. Exact pointers are in the table below.
Retained facts, not physical measurements
QuantityRecorded valueEvidence
Version 2 force-decoupled controls rejected5Original record
/primary/controls/force-decoupled/matched
Version 2 force-decoupled controls tested8Original record
/primary/controls/force-decoupled/total
Version 2 retained outcomevirtual_lab_coupled_controls_inconsistentOriginal record
/primary/outcome
Predeclared minimum margin1.00 pNOriginal record
/required_margin_newtons
Baseline worst-case control margin-8.76 pNOriginal record
/configurations/0/design/tiers/B/null_margin_newtons
Baseline worst-case signal margin-3.62 pNOriginal record
/configurations/0/design/tiers/B/signal_margin_newtons
All-improved worst-case control margin7.89 pNOriginal record
/configurations/7/design/tiers/B/null_margin_newtons
All-improved worst-case signal margin13.51 pNOriginal record
/configurations/7/design/tiers/B/signal_margin_newtons
All-improved retained tier-B outcomerobust_margin_positive_conditionalOriginal record
/outcomes/all/B

What comes next?

Predeclare the candidate stationarity requirement and detector-loss study. Continue virtual qualification with explicitly bounded imperfections; physical validation remains a separate evidence class, not a prerequisite for the next virtual study.

Layer three · Full technical record

Follow every fact to its retained source

The canonical research-slice envelope pins the exact retained bytes and fact locations. It does not assign a new scientific verdict or convert this study into tt.result.v1. Numeric pointers are provenance locations inside the JSON; the source files retain the original outcomes.

Download the content-addressed publication envelope

sha256:b1c00a9e7694017addd16c084eabc32b2877aae4751d1b16dcac72f74a41c16e